win,pipe: improve method of obtaining pid for ipc (#3765)
In the old version of uv_pipe_open, the parent process ID is used always. If the open pipe is used in the same process, the parent process will be obtained incorrectly. Now we first get the client pid and compare it with its own pid. If it is the same, then get the server pid. If the two are the same, then the pipe is from the same process. Fixes: https://github.com/libuv/libuv/issues/3766
This commit is contained in:
parent
1de43a1a17
commit
357d28a256
@ -1639,9 +1639,13 @@ static DWORD uv__pipe_get_ipc_remote_pid(uv_pipe_t* handle) {
|
||||
/* If the both ends of the IPC pipe are owned by the same process,
|
||||
* the remote end pid may not yet be set. If so, do it here.
|
||||
* TODO: this is weird; it'd probably better to use a handshake. */
|
||||
if (*pid == 0)
|
||||
*pid = GetCurrentProcessId();
|
||||
|
||||
if (*pid == 0) {
|
||||
GetNamedPipeClientProcessId(handle->handle, pid);
|
||||
if (*pid == GetCurrentProcessId()) {
|
||||
GetNamedPipeServerProcessId(handle->handle, pid);
|
||||
}
|
||||
}
|
||||
|
||||
return *pid;
|
||||
}
|
||||
|
||||
@ -2342,7 +2346,10 @@ int uv_pipe_open(uv_pipe_t* pipe, uv_file file) {
|
||||
|
||||
if (pipe->ipc) {
|
||||
assert(!(pipe->flags & UV_HANDLE_NON_OVERLAPPED_PIPE));
|
||||
pipe->pipe.conn.ipc_remote_pid = uv_os_getppid();
|
||||
GetNamedPipeClientProcessId(os_handle, &pipe->pipe.conn.ipc_remote_pid);
|
||||
if (pipe->pipe.conn.ipc_remote_pid == GetCurrentProcessId()) {
|
||||
GetNamedPipeServerProcessId(os_handle, &pipe->pipe.conn.ipc_remote_pid);
|
||||
}
|
||||
assert(pipe->pipe.conn.ipc_remote_pid != (DWORD)(uv_pid_t) -1);
|
||||
}
|
||||
return 0;
|
||||
|
||||